Specifications and performances in temperature @23°C ±5°C
Uncertainty is given in % of reading (CALYS 60 IS display) + fixed value.
Resistive probes: Measurement and simulation
Sensor |
Range (Input and Output) |
Resolution |
Accuracy / 1 year |
Pt100 (= 3850) |
-200°C to +850°C |
0.01°C |
0.02% RDG + 0.05°C |
Pt100 (= 3926) |
-200°C to +850°C |
0.01°C |
0.02% RDG + 0.05°C |
Pt100 (= 3902) |
-200°C to +650°C |
0.01°C |
0.02% RDG + 0.05°C |
Pt100 (= JIS SAMA) |
-200°C to +600°C |
0.01°C |
0.02% RDG + 0.05°C |
Pt200 (= 3851) |
-200°C to +850°C |
0.1°C |
0.02% RDG + 0.15°C |
Pt500 (= 3851) |
-200°C to +850°C |
0.1°C |
0.02% RDG + 0.1°C |
Pt1000 (= 3851) |
-200°C to +850°C |
0.01°C |
0.02% RDG + 0.1°C |
Cu10 (= 427) |
-70°C to +150°C |
0.1°C |
0.02% RDG + 0.4°C |
Cu100 (= 428) |
-180°C to +150°C |
0.1°C |
0.02% RDG + 0.05°C |
Ni100 (= 618) |
-60°C to +180°C |
0.1°C |
0.02% RDG + 0.05°C |
Ni120 (= 672) |
0°C to +150°C |
0.1°C |
0.02% RDG + 0.05°C |
Connections: 2, 3 and 4 wires
Rtd simulation excitation current: from 0.1 to 4 mA without incremental error
Rtd measurement excitation current: 0.2 mA
Rtd cable compensation: up to 100 m (for each wire)
Rtd cable compensation error (Pt100): ± 0.005°C/ of total wire
Maximum load resistance: 600 Ω @ 20 mA
Thermocouples: Measurement and simulation
Type |
Range |
Résolution |
Accuracy / 1 an |
J |
-210 to +1200°C |
0.01°C |
0.02% RDG + 0.1°C |
K |
-270 to +1370°C |
0.01°C |
0.02% RDG + 0.1°C |
T |
-270 to +400°C |
0.01°C |
0.02% RDG + 0.1°C |
R |
-50 to 1760°C |
0.1°C |
0.02% RDG + 0.2°C |
S |
-50 to 1760°C |
0.1°C |
0.02% RDG + 0.2°C |
B |
+50 à +1820°C |
0.1°C |
0.02% RDG + 0.3°C |
C |
0 to 2300°C |
0.1°C |
0.02% RDG + 0.2°C |
G |
0 to 2300°C |
0.1°C |
0.02% RDG + 0.3°C |
D |
0 to 2300°C |
0.1°C |
0.02% RDG + 0.3°C |
U |
-200 to +400°C |
0.01°C |
0.02% RDG + 0.1°C |
L |
-200 to +760°C |
0.01°C |
0.02% RDG + 0.1°C |
N |
-270 to +1300°C |
0.01°C |
0.02% RDG + 0.1°C |
E |
-270 to +1300°C |
0.1°C |
0.02% RDG + 0.1°C |
F |
0 to +1400°C |
0.1°C |
0.02% RDG + 0.1°C |
Display units: °C, °F et K
Resolution: 0.01°C / 0.01°F
Temperature scale: ITS90 and IPTS68
Reference junction compensation: internal automatic from -10°C to +55°C or external
Rj compensation drift: ± 0.002°C/°C (from -10 °C to +45 °C) - Class A Pt100
Input impedance: > 10 MΩ
Specifications and performances in pressure @23°C ±5°C
Pressure
Pressure media: AISI 316 SS compatible fluids (water, gas, and oil)
Temperature compensation: Automatic with built-in calibration matrix
Engineering units: mbar, bar, hPa, kPa, Mpa, kg/cm2, kg/m2, psi, mmH2O, cmH2O, mH2O, Torr, atm, lb/ft2, inH2O, FTH2O, mmHg, cmHg, mHg, inHg
Accuracy: accuracies given for 1 year, include non linearity, hysteresis, and repeatability.
Temperature coefficient inside the temperature compensated range: ± 0.002% RDG /°C
Compensation range: 0°C to 45°C
Measurement by external pressure module
Reference |
Range |
Resolution |
EPM000100G |
-100 / 100 mbar Gauge |
0.001 mbar |
EPM000500G |
-500 / 500 mbar Gauge |
0.01 mbar |
EPM001000G |
-0.95 / 1 bar Gauge |
0.01 mbar |
EPM002000G |
-0.95 / 2 bar Gauge |
0.01 mbar |
EPM007000G |
-0.95 / 7 bar Gauge |
0.1 mbar |
EPM200000G |
-0.95 / 20 bar Gauge |
0.1 mbar |
EPM035000G |
0.95 / 35 bar Gauge |
1 mbar |
EPM070000G |
0 / 70 bar Gauge |
1 mbar |
EPM150000G |
0 / 150 bar Gauge |
1 mbar |
EPM350000G |
0 / 350 bar Gauge |
10 mbar |
EPM700000G |
0 / 700 bar Gauge |
1 mbar |
EPM002000A |
2 bar Absolute |
0.01 mbar |
EPM020000A |
20 bar Absolute |
0.1 mbar |
Accuracy: ± 0.025% F.S.
Overpressure: 125% F.S.
Port: male, 1/4" BSP
Connection wire length: 2 m
Specifications and performances in process @23°C ±5°C
DC voltage: Measurement and simulation
Range |
Resolution |
Accuracy / 1 an |
-20 mV to +200 mV |
1 µV |
0.02% RDG + 3 µV |
-0,2 V to +2 V |
10 µV |
0.02% RDG + 10 µV |
-2 V to +12 V |
100 µV |
0.02% RDG + 100 µV |
Input impedance:
< 10 MΩ for ranges up to 2 V
> 500 kΩ for ranges up to 20 V
Output impedance (emf output): < 0.5 Ω with a maximum current of 0.5 mA
Output noise (at 300 Hz):
< 2 μV pp for ranges up to 200 mV
< 10 μV pp for ranges up to 2 V
< 80 μV pp for ranges up to 20 V
DC current: Measurement and simulation
With or without loop supply
Range |
Resolution |
Accuracy / 1 an |
0 mA to 21 mA |
0.1 µA |
0.02% RDG + 0.4 µA |
-5 mA to 50 mA |
0.1 µA |
0.02% RDG + 0.4 µA |
Input impedance: < 20 Ω at 1 mA
Maximum load resistance: 600 Ω at 21 mA
Loop supply: 12 V ± 5%
Resistance: Measurement and simulation
Type |
Range |
Resolution |
Accuracy / 1 an |
Measurement |
0 to 500 Ω |
10 mΩ |
0.02% RDG + 12 mΩ |
0 to 5000 Ω |
100 mΩ |
0.02% RDG + 120 mΩ |
Simulation |
0 to 500 Ω |
10 mΩ |
0.02% RDG + 40 mΩ |
0 to 5000 Ω |
100 mΩ |
0.02% RDG + 320 mΩ |
Connections: 2, 3 and 4 wires
Source resistance effects: ± 1 μV error for 1000 Ω source resistance
Simulation excitation current: from 0.1 to 4 mA without incremental error
Measurement excitation current: 0.2 mA
Maximum load resistance: 600 Ω @ 20 mA
Frequency, pulse: Measurement and simulation
Type |
Range |
Resolution |
Accuracy / 1an |
Frequency |
1 to 200 Hz |
0.001 Hz |
0.005% RDG + 0.001 Hz |
1 to 2 kHz |
0.01 Hz |
0.005% RDG + 0.01 Hz |
1 to 20 kHz |
0.1 Hz |
0.005% RDG + 0.1 Hz |
Pulse |
0 to 106 |
1 pulse |
0.01% RDG |
Input impedance: > 500 kΩ
Further features
Scaling in measurement and simulation modes |
Setup of zero and span programmable within -399999 and +999999 Scaling allows process signals to be displayed in % of FS or in all other units. This function also allows sensors to be corrected after a calibration. |
Square root |
In combination with scaling function |
Statistical functions |
hold, max, min, offset, zero, average |
Transmitters tests |
The feature enables any pressure or temperature transmitter to be controlled and calibrated with simultaneous display of input and output values in % F.S. or in actual unit. The measuring circuit is also able to power the loop for a direct connection to the transmitter under test. |
Ramps generation |
Autoramp and Autostep capability with Start, End, and Step programmable parameters Single and continuous cycle with Start, End, Rises, Soaks, and Falls programmable parameters The signal value setting uses a unique in-line single-digit setting mode or a direct numeric entry Direct keypad access to n.10 programmable memory stored values |
Transmitter function |
CALYS IS can be used as a transmitter. Any input signal (electric or pressure) can be converted into a 4-20 mA output. The galvanic insulation between the input and output channels allows this function o be used on the prcess directly. |
Switch test |
Temperature, signal and pressure switches can be tested using this advanced procedure. The calibrator will hold the display reading when the contact changes status. |
General specifications
Size |
290 x 98 x 57 mm |
Weight |
1.4 kg |
Display |
240 x 320 pixel liquid crystal graphical display with backlite and contrast control Display of result as table of values or trend curve |
Power supply |
230 V ± 10 %, 50/60 Hz |
Battery |
Type: NiMh Charging time: 8 h, 6 h if instrument switched off Life time: 8 h (Tc and V),3 h at 20 mA |
Communication ports |
RS 232 |
Storage capacity |
10 data with manual or automatic recall |
Environmental specifications
Reference range |
23°C ± 5°C (RH: 45 to 75 % condensing) |
Operating reference range |
-10 to 55°C (RH: 95 % non condensing) |
Storage temperature limits |
0°C to +60°C (without battery) |
Maximum height |
0 to 2000 m |
IP protection |
IP54 according to EN60529 |
Safety specifications
Protections |
- Thermal fuse
- High voltage suppressor
- Resistor-diode voltage limiter
|
Class |
class II 1G Ex ia IIC T4 (-20°C from T Ambient to +50°C) |
"SıCAKLıK KALIBRATöRü" AOIP CALYS 60 IS MULTIFONKSIYONEL PROSES KALIBRATöRü-SıCAKLıK KALIBRATöRü(ATEX) | KRAFT TEKNIK ÖLçüM CIHAZLARı